High Level Interlock output PNP

SLR11-011P-10 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-011P-10A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-011P-20 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-011P-20A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-011P-3 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-011P-3A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-011P-5 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-011P-5A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011P-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys

SLR11-011PC-10 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-011PC-10A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-011PC-20 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-011PC-20A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-011PC-3 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-011PC-3A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-011PC-5 High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-011PC-5A High Level Safety Interlock Power to lock, Unique coding output PNP

SKU: SLR11-011PC-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-011P
  • Locking mode: Power to lock
  • Configuration: Advanced
  • Coding method: Unique coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys

SLR11-100P-10 High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-100P-10A High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-100P-20 High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-100P-20A High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-100P-3 High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-100P-3A High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-100P-5 High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-100P-5A High Level Safety Interlock Power to unlock, Universal coding output PNP

SKU: SLR11-100P-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-100P
  • Locking mode: Power to unlock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys