SLR11 High Level Safety Interlock

SLR11 High Level Safety Interlocks

Ensure unparalleled safety with SLR11 High Level Safety Interlocks. Designed for critical applications, these interlocks prevent hazardous situations by controlling access and machine operation. Explore our selection of robust and reliable SLR11 interlocks to enhance workplace safety and meet stringent regulatory requirements. Find the perfect solution for your needs and protect your personnel and equipment.

SLR11-000N-10 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-000N-10A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-000N-20 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-000N-20A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-000N-3 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-000N-3A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-000N-5 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-000N-5A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000N-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys

SLR11-000NC-10 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-000NC-10A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-000NC-20 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-000NC-20A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-000NC-3 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-000NC-3A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-000NC-5 High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-000NC-5A High Level Safety Interlock Power to lock, Universal coding output NPN

SKU: SLR11-000NC-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000N
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: NPN
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys

SLR11-000P-10 High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-10

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by locking

SLR11-000P-10A High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-10A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S10
  • Cable Length (m): 10
  • AUX: Output monitored by keys

SLR11-000P-20 High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-20

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by locking

SLR11-000P-20A High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-20A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S20
  • Cable Length (m): 20
  • AUX: Output monitored by keys

SLR11-000P-3 High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-3

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by locking

SLR11-000P-3A High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-3A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

SLR11-000P-5 High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-5

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by locking

SLR11-000P-5A High Level Safety Interlock Power to lock, Universal coding output PNP

SKU: SLR11-000P-5A

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: Leading wire
  • Cable model: SLR11-M12P10S5
  • Cable Length (m): 5
  • AUX: Output monitored by keys

SLR11 High Level Safety Interlock: Ensuring Process Safety and Reliability

The SLR11 High Level Safety Interlock is a critical component in industrial process control, designed to prevent overfilling of tanks and vessels, thereby mitigating potential hazards, environmental spills, and equipment damage. This robust safety device provides a reliable, independent layer of protection, adhering to stringent safety standards and regulations. Often deployed as part of a Safety Instrumented System (SIS), the SLR11 acts as a final safety barrier when primary control systems fail to maintain safe operating levels.

Key Features and Benefits of the SLR11

The SLR11 High Level Safety Interlock is characterized by its high reliability, accuracy, and fail-safe design. It typically incorporates redundant sensors, independent logic solvers, and diverse final elements (e.g., shut-off valves) to ensure a high Safety Integrity Level (SIL). Benefits include:

  • Overfill Protection: Prevents costly and dangerous overfilling incidents.
  • Enhanced Safety: Minimizes risk to personnel, environment, and assets.
  • Regulatory Compliance: Meets industry-specific safety standards and regulations (e.g., IEC 61508, IEC 61511).
  • Improved Process Availability: Reduces downtime associated with overfill incidents and related damage.
  • Remote Monitoring and Control: Allows for real-time monitoring and remote actuation for rapid response.

Applications and Industries

The SLR11 High Level Safety Interlock finds widespread application across various industries where liquid storage and transfer are critical processes. Common applications include:

  • Oil and Gas: Preventing tank overfills in refineries, storage terminals, and pipelines.
  • Chemical Processing: Ensuring safe handling and storage of hazardous chemicals.
  • Water and Wastewater Treatment: Protecting against overflows in tanks and reservoirs.
  • Pharmaceutical Manufacturing: Maintaining precise liquid levels in reactors and storage vessels.
  • Food and Beverage: Safeguarding against spills and contamination in production processes.

Choosing the right SLR11 High Level Safety Interlock involves considering factors such as the specific application, process fluid properties, tank dimensions, required SIL level, and environmental conditions. Proper installation, commissioning, and regular testing are essential to maintain the interlock's integrity and ensure its continued effectiveness in preventing overfill incidents. Investing in a reliable SLR11 system is a proactive step towards creating a safer and more efficient operating environment.