Filter by category
- EMB Series Slide Unit
- SLE21 Safety Interlock Switch
- SLM11 Safety Door Switch(2 contacts)
- SLM11 Safety Door Switch(4 contacts)
- SLM13 Safety Door Switch
- SLM21 Safety Door Switch(6 contacts)
- SLR11 High Level Safety Interlock
- SSM11 Safety Door Switch (economic)
- SSR21 Contactless Safety Door Switch
- SSR22 Contactless Safety Door Switch
Coding method
- Unique coding 236
- Universal coding 236
Connector cable
Cable model
Contact type
- 1NC/1NO 2
- 1NC/1NO+1NC 8
- 1NC/1NO+1NC/1NO 20
- 1NC/1NO+2NC 20
- 1NC/2NO+1NC 4
- 1NC+1NC 4
- 1NC+1NC/2NO 4
- 1NC+2NC/1NO 4
- 1NC+3NC 12
- 1NO+1NC 4
- 1NO+2NC/1NO 4
- 1NO+3NC 12
- 2NC 2
- 2NC/1NO 2
- 2NC/1NO+1NC 4
- 2NC/1NO+1NC/1NO 8
- 2NC/1NO+2NC 8
- 2NC/1NO+2NC/1NO 8
- 2NC/1NO+3NC 8
- 2NC+1NC 8
- 2NC+1NC/1NO 20
- 2NC+2NC 20
- 2NO+2NC 8
- 3NC 2
- 3NC+1NC 12
- 3NC+1NC/1NO 8
- 3NC+2NC 8
- 3NC+2NC/1NO 8
- 3NC+3NC 8
Locking mode
- Power to lock 244
- Power to unlock 244
Showing 361–384 of 713 results
SLR11-001NC-5A High Level Safety Interlock Power to lock, Unique coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001N
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: NPN
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by keys
SLR11-001P-10 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by locking
SLR11-001P-10A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by keys
SLR11-001P-20 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by locking
SLR11-001P-20A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by keys
SLR11-001P-3 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by locking
SLR11-001P-3A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by keys
SLR11-001P-5 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by locking
SLR11-001P-5A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by keys
SLR11-001PC-10 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by locking
SLR11-001PC-10A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by keys
SLR11-001PC-20 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by locking
SLR11-001PC-20A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by keys
SLR11-001PC-3 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by locking
SLR11-001PC-3A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by keys
SLR11-001PC-5 High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by locking
SLR11-001PC-5A High Level Safety Interlock Power to lock, Unique coding output PNP
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-001P
- Locking mode: Power to lock
- Configuration: Standard
- Coding method: Unique coding
- Output: PNP
- Connector cable: M12 Connector
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by keys
SLR11-010N-10 High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by locking
SLR11-010N-10A High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S10
- Cable Length (m): 10
AUX: Output monitored by keys
SLR11-010N-20 High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by locking
SLR11-010N-20A High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S20
- Cable Length (m): 20
AUX: Output monitored by keys
SLR11-010N-3 High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by locking
SLR11-010N-3A High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S3
- Cable Length (m): 3
AUX: Output monitored by keys
SLR11-010N-5 High Level Safety Interlock Power to lock, Universal coding output NPN
Product Feature:
- With locking & monitoring function;
- Optional coding modes: Universal coding & unique coding;
- Independent redundant dual signal: In case of hazard caused by signal loop failure;
- Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
- Small size: 29.7*29.7 section size;
- Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.
Specifications:
- Series: SLR11-010N
- Locking mode: Power to lock
- Configuration: Advanced
- Coding method: Universal coding
- Output: NPN
- Connector cable: Leading wire
- Cable model: SLR11-M12P10S5
- Cable Length (m): 5
AUX: Output monitored by locking
Recently Viewed Products