SLR11-000PC-3A High Level Safety Interlock Power to lock, Universal coding output PNP

55 Items sold in last 12 months
3 People watching this product now!

Product Feature:

  • With locking & monitoring function;
  • Optional coding modes: Universal coding & unique coding;
  • Independent redundant dual signal: In case of hazard caused by signal loop failure;
  • Self-diagnose & cross-diagnose: Periodic double cross-diagnose improves security;
  • Small size: 29.7*29.7 section size;
  • Flexible installation: Directly installed on aluminum frame less than 30mm, brackets is no need.

Specifications:

  • Series: SLR11-000P
  • Locking mode: Power to lock
  • Configuration: Standard
  • Coding method: Universal coding
  • Output: PNP
  • Connector cable: M12 Connector
  • Cable model: SLR11-M12P10S3
  • Cable Length (m): 3
  • AUX: Output monitored by keys

StandardISO13849-1 (Category 4 PLe); IEC/EN60947-5-3
CertificateCE
Locking modelMechanical lock/ Power to lock
Safety outputNPN*2/ PNP*2
Response timeLock-unlock100ms (independent working)
Unlock-lockApproximate 1mA
Lock-unlock100ms (independent working)
Unlock-lockApproximate 1mA
LockingLock holding forceOver 2000N
Lock bolt insertion deviationLess then 2mm
Mechanical enduranceOver 1 million times(door operaing speed 1m/s)
Mechanical enduranceOver 1 million times(door operaing speed 1m/s)
Operating frequency1Hz
Minumum radius ofrevolving doorOver 220mm
Manual unlockingFront, back
Cascade linkingMax 20 pieces
Controloutput(OSSD output)Output typeTransistor output *2
Maximum load current≤200mA
Residual voltage (when it it on)<2.5V@200mA
Voltage when OFF≤2V @wire cable 5m
Leakage current≤0.5mA
Maximum load capacity2.2uF
Load connection resistance≤2.5Ω
AUX output(unsafeoutput)Output typeTransistor output
Output quantity1
Maximum load capacity50mA
Residual voltage (when ON status)≤2.5V @50mA
Externalinput(breakingcurrent)Safety input1.5mA*2
Reset/ EDM inputAbout 10mA*1
Locking control inputAbout 10mA*1
PowerPower supplyDC24V±15%
Rated capacity4.6W (no load)
ProtectionSafety circuit protection, current limit,overload protection, overvoltageprotection, stop & restart when overheat,reverse polarity protection, transient noise protection, invalid pulse protectio
EnvironmentresistanceHousing protection rateIP65
Operating ambienttemperature-20°c-55°c (no freezing)
Storage temperature-25°c-70°c (no freezing)
Operatingambient humidity5%-95%RH
Storage temperature5%-95%RH
Vibraion resistance10Hz-55Hz, dounle amplitude 2.0mm, 5minutes each in X, Y and Z directions
Shock resistance30g 6 times each in X, Y and Z directions
Risk time100ms
Restart time3.5s
MaterialNylon/ zinc alloy/ stainless steel
cable-SLR11-High-Level-Safety-Interlock
SIZE SLR11 High Level Safety Interlock 2
SIZE SLR11 High Level Safety Interlock 1

Installation examples

install SLR11 High Level Safety Interlock

Correct installation

Correct installation, main unit and sensing surface of actuator are facingeach other.

install SLR11 High Level Safety Interlock 1

Incorrect installation direction

interface SLR11 High Level Safety Interlock

Mutual interference

When multiple SLR11 used closely, they may malfunction due to mutual interference. In order to avoid mutual interference,please install interlock as below.

bracket SLR11 High Level Safety Interlock 1

SR11-B01

Inside mounting brackets

bracket SLR11 High Level Safety Interlock 1-1
bracket SLR11 High Level Safety Interlock 2

SR11-BL01

Slide mounting bracket (left opening)

bracket SLR11 High Level Safety Interlock 2-1
bracket SLR11 High Level Safety Interlock 3

SR11-BR01

Slide mounting bracket (right opening)

bracket SLR11 High Level Safety Interlock 3-1
bracket SLR11 High Level Safety Interlock 4

SR11-BL02

Hinge mounting bracket (left opening)

bracket SLR11 High Level Safety Interlock 4-1
bracket SLR11 High Level Safety Interlock 5

SR11-BR02

Hinge mounting bracket (right opening)

bracket SLR11 High Level Safety Interlock 5-1