ESCC1640RH3RZ-20 Vehicle Separator safety light curtain, resolution 45 mm, 16 beams, protective height 600 mm, output RS485 Passive mode
36 Items sold in last 12 months
3 People watching this product now!
SKU: ESCC1640RH3RZ-20 Category: Vehicle Separator Tags: Vehicle Separator Safety Curtain beam 16, Vehicle Separator Safety Light Curtain height 600 mm, Vehicle Separator safety light curtain resolution 45mm Brand: ESPE
- Series: ESCC1640
- Resolution (mm): 45
- Beams: 16
- Beam space (mm): 40
- Protective height (mm): 600
- Total height (mm): 685
- Output: RS485 Passive mode
- Outer cover: CRH-201-1650
- Sensing distance: 0.1-20m
| Supply voltage | DC24V±15% |
| Beam space | 20mm, 40mm |
| Resolution | 25mm, 45mm |
| Beams | 20mm beam space: 32, 6440mm beam space: 16, 32 |
| Wave length | 940nm |
| Capacity | <5W |
| Sensing distance | Max 20m (Remark: if light reflection, please let us know in advanced) |
| Anti-optical interference | 10000Lux (Incidence Angle I >5) |
| Sensing method | Through-beam type |
| Output mode | NPN, PNP, RS485 |
| Type of output(OSSD) | PNP/NPN semiconductors,current <200mA max, residual voltage: 1V max. leakage current: 1mA. (Expect voltage influenced by lengthen wire).RS485 output: Modbus communication protocol, customized protocol. |
| Protective circuit | Power supply over voltage protection, reverse polarity protection and output over current protection. |
| Output signal | OSSD 1 output blocking signal, OSSD 2 output abnormal signal |
| The Emission Indicator | Normal: The indicator is steady green |
| The Receiving Indicator | Normal: The green light is steady onAbnormal alignment: The indicator is steady redCP malfunction: Red & green light blink alternately. |
| Insulation Resistance | >100MΩ |
| Ambient Operating Temperature | -40ºC-55ºC |
| Storage Temperature | -55ºC-80ºC |
| Ambient Humidity | When the temperature is 20 ºC, the relative air humidity is less than 85% |
| Enclosure rating | IP65 |
| Housing cross-section | 35*50mm |
| Electrical parameters of the protective cover | Electrical parameters of the protective cover |
| Operating Voltage | 24V±10% |
| Working Current | 10A |
| Humidity Switch | Mechanical nylon film trigger switch relative temperature 20%-80% |
| Main Control Unit | When the heating unit of the starts, the red LED light at the front will grow |
| Cover Structure | Stainless Steel (201/304) |
| Cover | Self-adjusting heating glass |
| Heating Glass | Core 2 No. 14 standard cable will ground cable is required for heating glass (cable not provided) |
| Door Opening Method | Front-door opening mode |
| Door Closing Method | Front-door screws fixed |