ESRH-3A1B-E Relay input Two Hand Button, output 3NO 1NC
ESRH two hand button control module meet PLe safety requirement of ISO 13849-1, and is suitable for monitoring two hand button in industrial site with high safety requirements. It adopts dual-channel input mode, and has a detection ability with dual-channel synchronization time not exceeding 0.5s; it has a two-hand button control module with 3NO safety output contacts, and 1 NC auxiliary output contact.
Product feature:
- Design according to ISO13849-1 (Category 4 Ple).
- Relay output: 3NO and 1 NC auxiliary contacts.
- Inside circuit with cross-diagnose monitoring function.
- Visualized status indicator for easy diagnoses.
- Input power overvoltage protection.
| Standard level | |
| Reference standard | ISO 13849-1 |
| Safety level | ISO 13849-1 Category 4/Ple |
| Electric parameter | |
| Power supply | DC24V±10% |
| Consumption | <3W |
| Response time | <20ms |
| Suction buffer time | <100ms |
| Power-on restart time | <1s |
| Protective circuit | Overvoltage protection, reverse polarity protection |
| Safety input | Two hand button signal |
| Input synchronization | ≤500ms(Typical data200ms) |
| Safety output | 3NO contacts, and 1 NC auxiliary contacts |
| B10 data | Rated load: 400,000 times, low load: 2,000,000 times |
| Contact capacity | AC15:5A/250V;DC13:6A/24V |
| Electric lifetime | ≥100,000 times (1NO:5A 250VAC,Resistive load) |
| Mechanical lifetime | ≥10,000,000 times |
| Environment | |
| Vibration resistance | Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X,Y and Z direction |
| Impact resistance | Acceleration 10g, pulse duration 16ms, 1000 times each in X, Yand Z direction |
| Working temperature | -10℃~+55℃ |
| Storage temperature | -40℃~+85℃ |
| Protection level | Enclosure: IP40 Terminal: IP20 |
| Installation/ Structure | |
| Installation | 35mm DIN navigation |
| Wire size | 0.2~2.5mm² |
| Size | 117 x 100.6 x 22.5 |
Product Size

Wiring diagram

Panel function

Two hand button control module ESRH-3A1B supply 3 safety contacts output and 1 auxiliary contacts output in loop. Connectthe A1 terminal to positive of DC24V power supply, A2 terminal to the negative of power supply, when the signal of input loopS11 S21 is correct and reset loop active, the two hand button control module works.
Functional diagram

Product Installation
| Automatic reset | Input loop |
●ESRH-3A1B: connect Y1-Y2. ●When input loop S11 and S21 input active signal, component start to work. ●When input loop input active signal to two hand button, reset loop active, the K1 K2 of relay keep disconnecting, indicator light CH1 CH2 light on, safety contacts 13-14/23-24/33-34 close, auxiliary 41-42 disconnected. | ●Dual-channel input, connect S11 & S21 of relay to two handbutton respectively, at the mean time connect NO/NC of twohand button as diagram. ●Input loop disconnect (Input loop without active signal to ESRH-3A1B), reset loop active, the K1 &K2 of relay get disconnected,indicator CH1, CH2 light off, safety contacts 13-14/23-24/33-34get disconnected, auxiliary 41-42 close. |
Carefully read the manual before installation, and ensure power supply is cut off when wiring.Wiring with power is prohibited.